Home / Backup time / 100Ah with Small shop

100Ah - 12V lead-acid tubular - 70% assumed efficiency

How long does a 100Ah battery last with 4 tube lights + 2 fans + billing computer?

A 100Ah 12V tubular battery runs 4 tube lights + 2 fans + billing computer for about 1 hour. That load averages 420W, and the battery holds 420Wh usable once you apply 70% inverter efficiency and the 50% depth of discharge lead-acid batteries are limited to. 420Wh / 420W = 1 hours.

The arithmetic, line by line

A retail counter that cannot stop billing when the grid drops. Duty cycle matters here: Battery Buddy multiplies each appliance by the minutes it actually runs in an hour, so a fridge that cycles 40 minutes an hour is counted at two-thirds of its nameplate wattage instead of full blast.

Average hourly load, appliance by appliance
ApplianceWatts eachQtyMinutes per hourAverage draw
LED Tube Light20W460 min80W
Ceiling Fan70W260 min140W
Desktop Computer200W160 min200W
Total average hourly load420W

Why a 100Ah battery only gives you 420Wh

On paper a 100Ah 12V battery stores 100 x 12 = 1200Wh. You never get that. Lead-acid tubular plates are rated for roughly 50% depth of discharge, and the inverter loses more converting DC to AC, so the honest figure is 100 x 12 x 0.7 x 0.5 = 420Wh.

Entry-level tubular sold for one-room and shop backup. If you have already measured your own system with the efficiency estimator, put your real factor into the calculator — that single number moves the answer more than any other input.

What this result means for your outage

At 1 hour this is a High Load setup — Battery Buddy flags anything under 2 hours, because a single long outage will empty the bank before the grid returns.

  • Step up the bank: a 135Ah battery on the same load gives about 1 hour 21 minutes.
  • Swap induction ceiling fans for 30W BLDC fans — that alone removes roughly 40W per fan.
  • Move the heaviest appliance off the inverter circuit entirely rather than trying to out-size it.

Will the inverter actually hold this load?

Runtime and capacity are two different questions. With every appliance on at once this profile draws 420W continuous, which sizes to (420W / 0.8) x 1.25 on average draw and lands on a standard 800VA inverter.

The start-up surge test is the one most calculators skip. Desktop Computer spikes to about 240W for a second or two when its motor kicks in, so peak demand is 420W continuous + 240W surge = 660W. Against a 800VA inverter that is 18% headroom — it holds.

Efficiency is the number that actually moves the answer

Battery age, electrolyte level, cable thickness and terminal corrosion all show up as one thing: a lower effective efficiency. Here is the same battery and the same load across the realistic range.

The same setup at different real-world efficiencies
System efficiencyUsable energyEstimated backup
55%330Wh47 minutes
60%360Wh51 minutes
65%390Wh56 minutes
70% (default)420Wh1 hour
75%450Wh1 hour 4 minutes
80%480Wh1 hour 9 minutes

Run the two-hour test on the efficiency estimator to replace this guess with your own measured factor.

Other battery sizes against Small shop

If you are still choosing a battery, this is the whole shelf against exactly this load.

Every standard Indian battery size against Small shop
BatteryUsable energyEstimated backupBand
100Ah (this page)420Wh1 hourHigh load
120Ah504Wh1 hour 12 minutesHigh load
135Ah567Wh1 hour 21 minutesHigh load
150Ah630Wh1 hour 30 minutesHigh load
165Ah693Wh1 hour 39 minutesHigh load
180Ah756Wh1 hour 48 minutesHigh load
200Ah840Wh2 hoursModerate
220Ah924Wh2 hours 12 minutesModerate
250Ah1050Wh2 hours 30 minutesModerate

Other loads on a 100Ah battery

And this is the same 100Ah battery against every other load profile we model.

What else a 100Ah battery will carry
Load profileAverage drawEstimated backup
2 ceiling fans + 3 LED bulbs167W2 hours 31 minutes
1 ceiling fan + 2 LED bulbs88W4 hours 46 minutes
3 ceiling fans + 5 LED bulbs255W1 hour 39 minutes
2 fans + 4 lights + TV + WiFi router246W1 hour 42 minutes
Refrigerator + 2 fans + 4 LED bulbs276W1 hour 31 minutes
Laptop + WiFi router + 1 fan + 2 lights163W2 hours 35 minutes
2 fans + 6 lights + TV + refrigerator + WiFi404W1 hour 2 minutes
Air cooler + 2 LED bulbs198W2 hours 7 minutes
4 tube lights + 2 fans + billing computer (this page)420W1 hour
1 fan + 2 lights + 2 mobile chargers98W4 hours 17 minutes
TV + set-top box + 2 fans + 3 lights242W1 hour 44 minutes
3 BLDC fans + 6 LED bulbs144W2 hours 55 minutes

Frequently asked questions

How long will a 100Ah battery last with 4 tube lights + 2 fans + billing computer?

About 1 hour. The load averages 420W and the battery delivers 420Wh usable at 70% efficiency and 50% depth of discharge, so 420 / 420 = 1 hours.

Why does my 100Ah battery give less than 1 hours in practice?

Because 70% is an assumption, not your measurement. A battery two or three years old, a low electrolyte level, thin cabling or a charger that never completes a cycle in short grid windows all pull the effective factor down. At 55% the same setup gives 47 minutes. Measure yours with the efficiency estimator.

What inverter size suits 4 tube lights + 2 fans + billing computer?

A standard 800VA inverter. The sizing rule is (average load / power factor 0.8) x 1.25 safety margin, which on 420W gives 656VA and rounds up to the nearest retail tier.

Can I use the full 100Ah of the battery?

No. Lead-acid tubular batteries are rated for roughly 50% depth of discharge — draining past half state of charge sulphates the plates and shortens life sharply. That is why 100Ah x 12V = 1200Wh nominal becomes 420Wh usable.

How do I get more backup out of this setup without buying a bigger battery?

Cut the load, not the comfort. Replacing induction ceiling fans with 30W BLDC fans and any remaining CFLs with 9W LEDs typically removes 40-45W per fan and 6W per bulb. On this profile that is the difference between 1 hour and materially more, at a fraction of the cost of a second battery.

Does Battery Buddy sell batteries or recommend a brand?

No. Battery Buddy is a free, brand-neutral calculator from Flocci Technologies. It shows the formula for every number so you can check it against any dealer's quote, and it needs no sign-up.

Battery Buddy is free, needs no sign-up, sells no batteries and shows every formula it uses. It is built by Flocci Technologies, an India-first AI-native software studio behind 30+ apps that share one Flocci identity.