Home / Backup time / 100Ah with 1 fan, 2 lights

100Ah - 12V lead-acid tubular - 70% assumed efficiency

How long does a 100Ah battery last with 1 ceiling fan + 2 LED bulbs?

A 100Ah 12V tubular battery runs 1 ceiling fan + 2 LED bulbs for about 4 hours 46 minutes. That load averages 88W, and the battery holds 420Wh usable once you apply 70% inverter efficiency and the 50% depth of discharge lead-acid batteries are limited to. 420Wh / 88W = 4.8 hours.

The arithmetic, line by line

A single bedroom running through a night-time power cut. Duty cycle matters here: Battery Buddy multiplies each appliance by the minutes it actually runs in an hour, so a fridge that cycles 40 minutes an hour is counted at two-thirds of its nameplate wattage instead of full blast.

Average hourly load, appliance by appliance
ApplianceWatts eachQtyMinutes per hourAverage draw
Ceiling Fan70W160 min70W
LED Bulb9W260 min18W
Total average hourly load88W

Why a 100Ah battery only gives you 420Wh

On paper a 100Ah 12V battery stores 100 x 12 = 1200Wh. You never get that. Lead-acid tubular plates are rated for roughly 50% depth of discharge, and the inverter loses more converting DC to AC, so the honest figure is 100 x 12 x 0.7 x 0.5 = 420Wh.

Entry-level tubular sold for one-room and shop backup. If you have already measured your own system with the efficiency estimator, put your real factor into the calculator — that single number moves the answer more than any other input.

What this result means for your outage

At 4 hours 46 minutes this is a Moderate Load setup — it clears the 2-hour danger line but stays under 5 hours, so a long monsoon outage will need you to shed something.

  • Plan a shed order in advance: decide now which appliance gets switched off at the two-hour mark.
  • Measure your true efficiency before buying a bigger battery — a degraded battery mimics an undersized one.
  • Check the surge figure below before adding any motor-driven appliance.

Will the inverter actually hold this load?

Runtime and capacity are two different questions. With every appliance on at once this profile draws 88W continuous, which sizes to (88W / 0.8) x 1.25 on average draw and lands on a standard 600VA inverter.

The start-up surge test is the one most calculators skip. Ceiling Fan spikes to about 105W for a second or two when its motor kicks in, so peak demand is 88W continuous + 105W surge = 193W. Against a 600VA inverter that is 68% headroom — it holds.

Efficiency is the number that actually moves the answer

Battery age, electrolyte level, cable thickness and terminal corrosion all show up as one thing: a lower effective efficiency. Here is the same battery and the same load across the realistic range.

The same setup at different real-world efficiencies
System efficiencyUsable energyEstimated backup
55%330Wh3 hours 45 minutes
60%360Wh4 hours 5 minutes
65%390Wh4 hours 26 minutes
70% (default)420Wh4 hours 46 minutes
75%450Wh5 hours 7 minutes
80%480Wh5 hours 27 minutes

Run the two-hour test on the efficiency estimator to replace this guess with your own measured factor.

Other battery sizes against 1 fan, 2 lights

If you are still choosing a battery, this is the whole shelf against exactly this load.

Every standard Indian battery size against 1 fan, 2 lights
BatteryUsable energyEstimated backupBand
100Ah (this page)420Wh4 hours 46 minutesModerate
120Ah504Wh5 hours 44 minutesLow load
135Ah567Wh6 hours 27 minutesLow load
150Ah630Wh7 hours 10 minutesLow load
165Ah693Wh7 hours 53 minutesLow load
180Ah756Wh8 hours 35 minutesLow load
200Ah840Wh9 hours 33 minutesLow load
220Ah924Wh10 hours 30 minutesLow load
250Ah1050Wh11 hours 56 minutesLow load

Other loads on a 100Ah battery

And this is the same 100Ah battery against every other load profile we model.

What else a 100Ah battery will carry
Load profileAverage drawEstimated backup
2 ceiling fans + 3 LED bulbs167W2 hours 31 minutes
1 ceiling fan + 2 LED bulbs (this page)88W4 hours 46 minutes
3 ceiling fans + 5 LED bulbs255W1 hour 39 minutes
2 fans + 4 lights + TV + WiFi router246W1 hour 42 minutes
Refrigerator + 2 fans + 4 LED bulbs276W1 hour 31 minutes
Laptop + WiFi router + 1 fan + 2 lights163W2 hours 35 minutes
2 fans + 6 lights + TV + refrigerator + WiFi404W1 hour 2 minutes
Air cooler + 2 LED bulbs198W2 hours 7 minutes
4 tube lights + 2 fans + billing computer420W1 hour
1 fan + 2 lights + 2 mobile chargers98W4 hours 17 minutes
TV + set-top box + 2 fans + 3 lights242W1 hour 44 minutes
3 BLDC fans + 6 LED bulbs144W2 hours 55 minutes

Frequently asked questions

How long will a 100Ah battery last with 1 ceiling fan + 2 LED bulbs?

About 4 hours 46 minutes. The load averages 88W and the battery delivers 420Wh usable at 70% efficiency and 50% depth of discharge, so 420 / 88 = 4.8 hours.

Why does my 100Ah battery give less than 4.8 hours in practice?

Because 70% is an assumption, not your measurement. A battery two or three years old, a low electrolyte level, thin cabling or a charger that never completes a cycle in short grid windows all pull the effective factor down. At 55% the same setup gives 3 hours 45 minutes. Measure yours with the efficiency estimator.

What inverter size suits 1 ceiling fan + 2 LED bulbs?

A standard 600VA inverter. The sizing rule is (average load / power factor 0.8) x 1.25 safety margin, which on 88W gives 138VA and rounds up to the nearest retail tier.

Can I use the full 100Ah of the battery?

No. Lead-acid tubular batteries are rated for roughly 50% depth of discharge — draining past half state of charge sulphates the plates and shortens life sharply. That is why 100Ah x 12V = 1200Wh nominal becomes 420Wh usable.

How do I get more backup out of this setup without buying a bigger battery?

Cut the load, not the comfort. Replacing induction ceiling fans with 30W BLDC fans and any remaining CFLs with 9W LEDs typically removes 40-45W per fan and 6W per bulb. On this profile that is the difference between 4 hours 46 minutes and materially more, at a fraction of the cost of a second battery.

Does Battery Buddy sell batteries or recommend a brand?

No. Battery Buddy is a free, brand-neutral calculator from Flocci Technologies. It shows the formula for every number so you can check it against any dealer's quote, and it needs no sign-up.

Battery Buddy is free, needs no sign-up, sells no batteries and shows every formula it uses. It is built by Flocci Technologies, an India-first AI-native software studio behind 30+ apps that share one Flocci identity.