Home / Backup time / 200Ah with Full home load

200Ah - 12V lead-acid tubular - 70% assumed efficiency

How long does a 200Ah battery last with 2 fans + 6 lights + TV + refrigerator + WiFi?

A 200Ah 12V tubular battery runs 2 fans + 6 lights + TV + refrigerator + WiFi for about 2 hours 5 minutes. That load averages 404W, and the battery holds 840Wh usable once you apply 70% inverter efficiency and the 50% depth of discharge lead-acid batteries are limited to. 840Wh / 404W = 2.1 hours.

The arithmetic, line by line

Everything the family expects to keep working — the honest worst case. Duty cycle matters here: Battery Buddy multiplies each appliance by the minutes it actually runs in an hour, so a fridge that cycles 40 minutes an hour is counted at two-thirds of its nameplate wattage instead of full blast.

Average hourly load, appliance by appliance
ApplianceWatts eachQtyMinutes per hourAverage draw
Ceiling Fan70W260 min140W
LED Bulb9W660 min54W
LED TV (43-inch)100W160 min100W
Refrigerator (190L)150W140 min100W
WiFi Router10W160 min10W
Total average hourly load404W

Why a 200Ah battery only gives you 840Wh

On paper a 200Ah 12V battery stores 200 x 12 = 2400Wh. You never get that. Lead-acid tubular plates are rated for roughly 50% depth of discharge, and the inverter loses more converting DC to AC, so the honest figure is 200 x 12 x 0.7 x 0.5 = 840Wh.

Large tubular for 3BHK homes, shops and clinics. If you have already measured your own system with the efficiency estimator, put your real factor into the calculator — that single number moves the answer more than any other input.

What this result means for your outage

At 2 hours 5 minutes this is a Moderate Load setup — it clears the 2-hour danger line but stays under 5 hours, so a long monsoon outage will need you to shed something.

  • Plan a shed order in advance: decide now which appliance gets switched off at the two-hour mark.
  • Measure your true efficiency before buying a bigger battery — a degraded battery mimics an undersized one.
  • Check the surge figure below before adding any motor-driven appliance.

Will the inverter actually hold this load?

Runtime and capacity are two different questions. With every appliance on at once this profile draws 454W continuous, which sizes to (404W / 0.8) x 1.25 on average draw and lands on a standard 800VA inverter.

The start-up surge test is the one most calculators skip. Refrigerator (190L) spikes to about 450W for a second or two when its motor kicks in, so peak demand is 454W continuous + 450W surge = 904W. Against a 800VA inverter that is an overload — the inverter will beep and cut out.

Efficiency is the number that actually moves the answer

Battery age, electrolyte level, cable thickness and terminal corrosion all show up as one thing: a lower effective efficiency. Here is the same battery and the same load across the realistic range.

The same setup at different real-world efficiencies
System efficiencyUsable energyEstimated backup
55%660Wh1 hour 38 minutes
60%720Wh1 hour 47 minutes
65%780Wh1 hour 56 minutes
70% (default)840Wh2 hours 5 minutes
75%900Wh2 hours 14 minutes
80%960Wh2 hours 23 minutes

Run the two-hour test on the efficiency estimator to replace this guess with your own measured factor.

Other battery sizes against Full home load

If you are still choosing a battery, this is the whole shelf against exactly this load.

Every standard Indian battery size against Full home load
BatteryUsable energyEstimated backupBand
100Ah420Wh1 hour 2 minutesHigh load
120Ah504Wh1 hour 15 minutesHigh load
135Ah567Wh1 hour 24 minutesHigh load
150Ah630Wh1 hour 34 minutesHigh load
165Ah693Wh1 hour 43 minutesHigh load
180Ah756Wh1 hour 52 minutesHigh load
200Ah (this page)840Wh2 hours 5 minutesModerate
220Ah924Wh2 hours 17 minutesModerate
250Ah1050Wh2 hours 36 minutesModerate

Other loads on a 200Ah battery

And this is the same 200Ah battery against every other load profile we model.

What else a 200Ah battery will carry
Load profileAverage drawEstimated backup
2 ceiling fans + 3 LED bulbs167W5 hours 2 minutes
1 ceiling fan + 2 LED bulbs88W9 hours 33 minutes
3 ceiling fans + 5 LED bulbs255W3 hours 18 minutes
2 fans + 4 lights + TV + WiFi router246W3 hours 25 minutes
Refrigerator + 2 fans + 4 LED bulbs276W3 hours 3 minutes
Laptop + WiFi router + 1 fan + 2 lights163W5 hours 9 minutes
2 fans + 6 lights + TV + refrigerator + WiFi (this page)404W2 hours 5 minutes
Air cooler + 2 LED bulbs198W4 hours 15 minutes
4 tube lights + 2 fans + billing computer420W2 hours
1 fan + 2 lights + 2 mobile chargers98W8 hours 34 minutes
TV + set-top box + 2 fans + 3 lights242W3 hours 28 minutes
3 BLDC fans + 6 LED bulbs144W5 hours 50 minutes

Frequently asked questions

How long will a 200Ah battery last with 2 fans + 6 lights + TV + refrigerator + WiFi?

About 2 hours 5 minutes. The load averages 404W and the battery delivers 840Wh usable at 70% efficiency and 50% depth of discharge, so 840 / 404 = 2.1 hours.

Why does my 200Ah battery give less than 2.1 hours in practice?

Because 70% is an assumption, not your measurement. A battery two or three years old, a low electrolyte level, thin cabling or a charger that never completes a cycle in short grid windows all pull the effective factor down. At 55% the same setup gives 1 hour 38 minutes. Measure yours with the efficiency estimator.

What inverter size suits 2 fans + 6 lights + TV + refrigerator + WiFi?

A standard 800VA inverter. The sizing rule is (average load / power factor 0.8) x 1.25 safety margin, which on 404W gives 631VA and rounds up to the nearest retail tier.

Can I use the full 200Ah of the battery?

No. Lead-acid tubular batteries are rated for roughly 50% depth of discharge — draining past half state of charge sulphates the plates and shortens life sharply. That is why 200Ah x 12V = 2400Wh nominal becomes 840Wh usable.

How do I get more backup out of this setup without buying a bigger battery?

Cut the load, not the comfort. Replacing induction ceiling fans with 30W BLDC fans and any remaining CFLs with 9W LEDs typically removes 40-45W per fan and 6W per bulb. On this profile that is the difference between 2 hours 5 minutes and materially more, at a fraction of the cost of a second battery.

Does Battery Buddy sell batteries or recommend a brand?

No. Battery Buddy is a free, brand-neutral calculator from Flocci Technologies. It shows the formula for every number so you can check it against any dealer's quote, and it needs no sign-up.

Battery Buddy is free, needs no sign-up, sells no batteries and shows every formula it uses. It is built by Flocci Technologies, an India-first AI-native software studio behind 30+ apps that share one Flocci identity.